programming procedure (continued)
Operator Input Terminal – Programming Procedure – Standard Software
MANUAL MODE F1=INCH
F2=SINGLE FEED MODE
F4=EXIT MANUAL MODE
CYCLE ROLL WITH KEYS
F2=SINGLE FEED
If the operator presses F2 then the
following screen is displayed. The
single feed mode is active and every
time the F1 key is pressed then the
feed will cycle and move the distance
indicated on the feed length line.
JOB#=00 FL=000.000
F1=FEED SINGLE LNGTH
F2=CUT F3=SINGLE CYC
F4=EXIT (SINGLE FEED)
Pressing F4 once resets the program
to the manual mode display. Pressing
the F4 key twice resets the program
to the main menu display. If the F4
key was pressed twice the following
screen is displayed.
MAIN SELECTION MENU
F1=JOB# F2=MANUAL
F3=AUTOMATIC CYCLE
F4=REVIEW JOB PROGRAM
F3=AUTOMATIC CYCLE
You can now select between batch or
continuous mode
SELECT CONTINUOUS OR
BATCH CYCLE F1=BATCH
F2=CONTINUOUS CYCLE
F4=EXIT TO MAIN MENU
F2=CONTINUOUS
If the F2 key was pressed then the
servo will be in the auto total mode
and the following screen appears.
AUTOMATIC TOT=000000
JOB#=00 CUT=O.150
FL=000.000 SPEED=100
ACCEL=OO1% F4=RETURN
Pressing the F4 key, stops the
automatic cycle and the main menu
screen appears.
MAIN SELECTION MENU
F1=JOB# F2=MANUAL
F3=AUTOMATIC CYCLE
F4=REVIEW JOB PROGRAM
F3=AUTOMATIC CYCLE
If the feed has been properly set up,
tested in manual, press electrically
interlocked with feed, feed and pilot
switches wired to the correct
terminals, then pressing the F3 key
will display the following screen.
SELECT CONTINUOUS OR
BATCH CYCLE F1=BATCH
F2=CONTINUOUS CYCLE
F4=EXIT TO MAIN MENU
F1 =BATCH
If the F1 key was pressed then the
servo will be in the auto batch mode
and the following screen appears.
BATCH SETTING=000000
BATCH COUNTER=000000
F1=RESET BATCH COUNT
F4=CONTINUE WITH COUNT
If F1 (reset batch count) is pressed
then the batch count will be reset
to its preset valve. If F4 (continue
with count) is pressed the batch
count will remain at its present
value. Either F1 or F4 will lead to the
following screen.
AUTOMATIC BATCH=000000
JOB#=XX CUT=0.XXX
FL=XXX.XXX SPEED=XXX%
ACCEL=XXX% F4=RETURN
Pressing the F4 key, stops the
automatic cycle and the main menu
screen appears.
When the automatic screen is
displayed, all keys except the F4 key
are inactive. Every time the press
cycles and trips the feed switch,
the feed will cycle once per the
parameters displayed on the screen.
If the feed encounters excessive
material drag while feeding or the
material being moved encounters
a restriction that stops the material
forward movement then a servo fault
can occur. If this happens then the
following screen is displayed.
DRIVE FAULT OCCURED
NOTE TYPE OF FAULT––
(xxx)
Example of fault – (2) = motor over
temperature.
Look up fault code printout listed in
this manual.
To reset the fault, the master on-off
switch has to be cycled which will
reset the controller. The material path
should be checked for obstruction and
parallelism to the die. If all this seems
to be satisfactory and another fault oc-
curs the factory should be consulted.
MAIN SELECTION MENU
F1=JOB# F2=MANUAL
F3=AUTOMATIC CYCLE
F4=REVIEW JOB PROGRAM