RAPID-AIR CORPORATION4601 KISHWAUKEE ST. • ROCKFORD, IL 61109-2925Phone: (815) 397-2578 • Fax: (815) 398-3887 • Web Site: www.rapidair.comSERVO FEEDO
9 PRETEST FOR KBX FEED AND PRESS WITHOUT MATERIAL Now that your KBX feed unit has been mounted and the cables have been attached, you can proceed wit
10 LOADING MATERIAL INTO THE SERVO FEED Upon the satisfactory completion of all the tests, you should be ready to load a strip of material into the s
11 SERVO INTERFACING EXPLANATION A. TAUT STOCK INPUT (J52)TBI-3) This is a normally open contact from a switch or device that monitors the loop of
12 F. STANDARD PROGRAM- DATA INSTRUMENTS INTERFACE (J52)TB1-7) With the jumper in place, the standard program is active. Remove jumper, recycle powe
13 RESET JOB PARAMETERS The reset job parameters routing should be used with special caution. We incorporated it as a user function for two reasons
14 SERVO To help you to enter a job from the keypad, let’s create an example. We will use a feed length of three inches and want to run at 100 strok
15 FEED ARC To explain how the “feed arc” is related to the servo feed calculation, we must first explain what the feed arc is in relation to
16 OPERATOR INPUT TERMINAL - PROGRAMMING PROCEDURE-STANDARD SOFTWARE The intent of this section is to familiarize the operator with the program flow
17 The job number screen displays (3) choices for the operator. In the first choice, F1=Program parameters, the operator can enter or change the feed
18 In order to advance material into the die, using the servo feed, the operator has to be in the manual mode. Pressing F2 on the keypad will cause t
1 RAPID-AIR START UP SECTION (100-200-300 S SERIES) Congratulations on purchasing a Rapid-Air Servo. Not only did you receive a complete servo uni
19 If the operator presses F2 then the following screen is displayed. The single feed mode is active and every time the F1 key is pressed then the fe
20 If the feed has been properly set up and tested in manual and the press has been electrically interlocked with the feed, feed switch is wired to th
21 If this screen is displayed then the control cabinet has to be opened and the Pac-Sci drive has to be checked. To reset the fault, the master on-
22 The only section that has not been covered in this write-up is the ramp adjust mode. The ramp adjusts how fast the servo motor gets up to speed an
23 DRIVE ROLL PARALLELISM ADJUSTMENT Every KBX feed has an eccentric adjustment screw to adjust the upper roller to be in parallel to the lower rolle
24 TROUBLESHOOTING CHART PROBLEM CAUSE REMEDY No power indication
25 TROUBLESHOOTING CHART (cont.) PROBLEM CAUSE REMEDY Material feeds off
26 SERVO FAULT DISPLAY The Pacific Scientific drive has a list of internal faults and displays the number of that fault on it’s readout located on
27 FAULT CODE (Predefined Variable, Integer, Status Variable, Read-Only) Guidelines - 0 means the drive is not faulted and not enabled, while 8 means
28 MOTOR SERVICE The servo motor is flanged mounted and secured with four socket head cap screws. The motor removal has to be done in a sequence as d
2 TABLE OF CONTENTS CHARTS AND DRAWINGS DIRECTORY pg. 3 INTRODUCTION
29 REASSEMBLY OF UNIT Prior to assembly, attention must be given to three points of contact that require an application of Moly-Cote, Lubriplate or ot
30 PRECAUTIONS & SAFETY NEVER - Put screwdrivers or foreign materials in feed rolls NEVER - Hold onto material as it is being fed through the se
31 WARRANTY ALL SALES BY THE COMPANY ARE MADE SUBJECT TO THE FOLLOWING TERMS AND CONDITIONS. PLEASE READ. WARRANTY - The Company warrants, for a pe
32 KBX Servo Straightener OPERATION For set up only, place a short length of stock about four feet on bottom rolls, between the pinch rolls. Set the
33
3 CHARTS AND DRAWINGS 104KBX 108KBX
4 INTRODUCTION The Rapid-Air servo feed carries with it the quality and reliability you have grown to expect from a Rapid-Air product. The motion co
5 INSTALLATION AND MECHANICAL SETUP OF SERVO FEED The shipping container should contain: 1 Mechanical Servo Feed/Straightener -Standard 1 Console
6 INSTALLATION AND MECHANICAL SETUP OF MOUNTING BRACKET The cast mounting bracket is available for mounting the KBX feed directly to the bolster plat
7 ELECTRICAL CABLES AND AIR LINE 230 VAC INPUT The required input voltage to the control is 230 Vac, 3 Ph, 60 Hz. The amperage needed is 10 amps for
8 INTERFACING SERVO FEED WITH A PRESS The KBX unit is a slave to the press therefore it needs a command from the press to operate in the automatic mo
Comentários a estes Manuais